Descrizione
Specifications
General information
Application Code | III | ||
Type Version | IDC | ||
Lamp Type | TL5 HE | ||
Number of Lamps | 2 piece/unit | ||
Number of Products on MCB (16A Type B) (Nom) | 28 | ||
Automatic Restart | Yes | ||
Operating and electrical
Input Voltage | 220 to 240 V | ||
Input Frequency | 50 to 60 Hz | ||
Operating Frequency (Nom) | 45 kHz | ||
Ignition Method | Programmed Start | ||
Crestfactor (Max) | 1.7 | ||
Power Factor 100% Load (Nom) | 0.99 | ||
Ignition Time (Max) | 0.9 s | ||
Mains Voltage Performance (AC) | -8%-+6% | ||
Mains Voltage Safety (AC) | -10%-+10% | ||
Earth Leakage Current (Nom) | 0.5 mA | ||
Inrush Current Width | 0.25 ms | ||
Constant Wattage Deviation | -2%/+2% | ||
Ballast Factor (Nom) | 1 | ||
Power Losses (Nom) | 2-5.5 W | ||
Inrush Current Peak (Max) | 24 A | ||
Efficiency at full load [%] | 93.30000000000001 % | ||
Wiring
Connector Type Input Terminals | WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring] | |
Cable Capacity Output Wires Mutual (Nom) | 200 pF | |
Connector Type Output Terminals | WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring] | |
Cable Length Hot Wiring | 0.75 m | |
Wire Striplength | 8.0-9.0 mm | |
Dual Fixture Master/Slave | Not applicable [ Master/Slave oper. not applicable] | |
Input Terminal Cross Section | 0.50-1.00 mm² | |
Output Terminal Cross Section | 0.50-1.00 mm² | |
Cable Capacity Output Wires to Earth (Nom) | 200 pF | |
System characteristics
Rated Ballast-Lamp Power | 14-35 W | ||
Rated Lamp Power on TL5 HE | 14/35 W | ||
System Power on TL5 HE | 36.8/75.6 W | ||
Lamp Power on TL5 HE | 28.0/70.0 W | ||
Power Loss on TL5 HE | 2.8/5.6 W | ||
Temperature
T-Ambient (Max) | 60 °C | ||
T-Ambient (Min) | -25 °C | ||
T-Storage (Max) | 80 °C | ||
T-Storage (Min) | -40 °C | ||
T-Case Lifetime (Nom) | 80 °C | ||
T-Case Maximum (Max) | 80 °C | ||
T-Ignition (Max) | 60 °C | ||
T-Ignition (Min) | -25 °C | ||
Mechanical and housing
Housing | L360x30x22 | |
Emergency operation
Nominal Light Output After 60 Seconds | 100% of EBLF | ||
Battery Voltage Lamp Ignition | 176-276 V | ||
Normal Operating Voltage (DC) | 220-240 V | ||
Battery Voltage Lamp Operation | 176-276 | ||
Battery Voltage Guaranteed Operation | 176-275 V | ||
Battery Voltage Guaranteed Ignition | 186-275 V | ||
Emergency Ballast Lumen Factor (EBLF) (Nom) | 100 % | ||
Nominal Light Output After 5 Seconds | 50% of EBLF | ||
Approval and application
Energy Efficiency Index | A2 BAT | ||
IP Classification | IP 20 [ Ingress Protection 20] | ||
EMI 9 kHz … 30 MHz | EN55015 | ||
EMI 30 MHz … 1000 MHz | – | ||
Safety Standard | IEC 61347-2-3 | ||
Performance Standard | IEC 60929 | ||
Quality Standard | ISO 9000:2000 | ||
Environmental Standard | ISO 14001 | ||
Harmonic Current Emission Standard | IEC 61000-3-2 | ||
EMC Immunity Standard | IEC 61547 | ||
Vibration Standard | IEC68-2-6 F c | ||
Bumps Standard | IEC 68-2-29 Eb | ||
Humidity Standard | EN 61347-2-3 clause 11 | ||
Approval Marks | CE markingENEC certificateVDE-EMV certificate | ||
Temperature Marking | Yes | ||
Emergency Standard | IEC 60598-2-22 | ||
Hum And Noise Level | < 30 dB(A) | ||
Product data
Full product code | 872790090503800 | ||
Order product name | HF-P 2 14-35 TL5 HE III 220-240V | ||
EAN/UPC – Product | 8711500999238 | ||
Order code | 913713031166 | ||
Numerator – Quantity Per Pack | 1 | ||
Numerator – Packs per outer box | 12 | ||
Material Nr. (12NC) | 913713031166 | ||
Net Weight (Piece) | 0.245 kg | ||
Recensioni